Key Features
  • VERSATILE USE

    With extensive modes and monitoring parameters, in-built turbine, battery backup, and compact form factor, the ICV is easy to use in any location within a hospital, or for transport within or outside the facility.

  • ADVANCED VENTILATION MODES

    The ICV comes standard with a range of invasive and non-invasive ventilation modes to fit the clinical needs of infant, pediatric, and adult patients.

  • SOPHISTICATED MONITORING

    Combining extensive monitoring parameters and respiratory diagnostics with dedicated display pages, the ICV can measure, display, store, and export the information needed for precise, high-quality care.

  • FULLY PORTABLE

    The ICV’s trolley is designed to easily hold or move the ventilator and accessories, including an oxygen cylinder bracket, humidifier, and circuit support arm.

  • SMART CPR MODE

    The innovative CPR mode gives step-by-step audible and visual instructions for performing CPR and breathing as per AHA and ERC’s latest guidelines.

Image 1 of 1
    • VENTILATION PARAMETERS

      Tidal volume: 2 – 2000 mL (Additional accessories required for infant use)

      Insp. pressure: 1 – 90 cmH2O

      Maximum flow: > 180 L/min

      Resp. rate: 0 – 150 bpm

      Insp. time: 0.2 – 10 sec

      Insp. pause: 0% – 60%

      FiO2: 21% – 100%

    • VENTILATION MODES

      Modes for all patient types: PCV, P-A/C, P-SIMV, CPAP/PSV, CPR, PRVC-SIMV, APRV, BIPPV, HFNC

      Adult/Peds patients only: IPPV, V-A/C, V-SIMV

    • MONITORING

      Weaning: P0.1, RSBI, WOB

      Real-time waveforms: Pressure, Volume, Flow, EtCO2

      Loops: P-V, F-V, P-F, EtCO2-V

      Trends: 1, 15, 30, or 60 minutes

      Tools: Suction, Nebulization, Dynamic lung, P-V tool, Lung recruitment

      Event log: Up to 5000 events

      Utilities: Automated self-checks, Leak and compliance compensation

    • ACCESSORIES

      Workstation: Trolley, circuit support arm, active humidifier, cylinder support

      Ventilation Accessories: Reusable accessories, consumables starter pack, EtCO2 module

    • ELECTRICAL AND GAS SUPPLIES

      Input voltage: 100 – 240 VAC, 50/60 Hz

      Power: <140 W

      Battery: Internal, max 6 hr backup

      High pressure oxygen input: DISS, 280 – 600 kPa (40.6 – 87 psi)

      Low pressure oxygen input: Quick connect, 15 L/min, 100 kPa (14 psi)

      Air supply: Integrated turbine, filtered

      Protection: IP43

    • PHYSICAL DIMENSIONS

      Weight: 6.2 kg (13.7 lb) without trolley

      Display: 10.4 in TFT color touchscreen

    • ENVIRONMENTAL

      Temperature:

      -10°C – 50°C (Operation)

      -20°C – 60°C (Storage)

      Humidity: 10 – 95% RH

      Pressure: 50 kPa – 110 kPa atmospheric

      Interfaces: VGA, USB, RS232, Ethernet, CO2

  • Gradian ICV Specifications Sheet

    Mar 21, 2024

    Gradian ICV User Guide

Request a Quote

If you want to partner with Gradian Health Systems, learn more about us, or purchase a Gradian product, please contact us here.

Name(Required)
This field is for validation purposes and should be left unchanged.

Related Articles

See More
Jul 24, 2023

Strengthening Healthcare in Tanzania: Gradian Health Systems Donates Three Intensive Care Ventilators (ICVs) to Muhimbili National Hospital